Split type rapid temperature change test chamber relocation needs attention

What is common in daily life is the split type air conditioner, so what is the split type rapid temperature change test box? There are two reasons for the split structure design in the environmental test equipment. The first one is because the size of the door or freight elevator is limited. The second reason is to design the component body to be carried in. The second reason is that the user has precise requirements on the vibration amplitude of the sample. Since the operation of the compressor will have vibration effects on the sample when the device is cold, we also use the split type. design.

The split type rapid temperature change box does not want to be as simple as the whole test box, so we must pay attention to the following points when moving:

1. It is recommended to pack the equipment before handling, so as to avoid the phenomenon of scratching during transportation. At the same time, the casters of the equipment should be fixed with wooden boards, thus effectively avoiding the damage of the casters and preventing vibration during transportation. The bumps cause problems with the device.

Rapid temperature change test box packaging

2. During the handling process, the split type rapid temperature change box is prohibited from tilting. If there is a tilting, it will cause the freezing oil to overflow, so the compressor is likely to be scrapped.

3. When unloading, it is recommended not to carry it manually unless it is absolutely necessary. It is important to consider the forklift. If the equipment is placed on the first floor, use the manual hydraulic forklift to place the equipment in the corresponding position. If it is placed on the upper floor, consider the elevator. Is the size enough?

Relocation is also a matter of learning. Of course, in the process of carrying a split-type rapid temperature change box, it is of course the most important safety of the person. Be careful and safe, and you and me!

Split type rapid temperature change test box technical parameters:

1. Temperature range: -60 ° C ~ 150 ° C

2. Temperature uniformity: ≤ 2 ° C (when no load)

3. Temperature fluctuation: ±0.5°C (at no load)

4. Humidity range: 10%~98% RH

5. Humidity uniformity: +2% -3% RH

6. Humidity fluctuation: ±2%

Refer to temperature and humidity to control the range map, no active wet and hot load

7. Cooling rate: 85 ° C ~ -60 ° C ≤ 30 min (linear, loaded, no heat)

8. Heating rate: -60°C~85°C≤30min (linear, loaded, no heat)

9. 1~9999H

10. AC380V±10% 50±0.5Hz (three-phase five-wire system)

Split type rapid temperature change test chamber material structure:

1. Outer box material: It is made of high quality (t=1.2mm) A3 steel plate CNC machine tool, and the surface of the outer casing is sprayed, which is more beautiful and beautiful.

2. Inner box material: imported high-grade stainless steel (SUS304)

3. Insulation material: rigid polyurethane foam + fiberglass

4. Door insulation material: fiberglass cotton

Split type rapid temperature change test chamber relocation needs attention

Split type rapid temperature change test box physical map

Pet Leashes

Pet Leashes,Telescopic Traction Rope For Large Dogs,Extendable Dog Lead,Flexi Retractable Dog Lead