Our company is a supplier of ELISA kits. The price is fair. The pre-sale, in-sale and after-sale services are at your service. Provide free test service, please call us!
Human Insulin Autoantibodies (IAA) Enzyme Linked Immunoassay (ELISA)
Kit instruction manual
This reagent is for research use only
Purpose: This kit is used to determine the content of insulin autoantibodies (IAA) in human serum, plasma and related liquid samples.
Experimental principle:
This kit uses the double antibody sandwich method to determine the level of human insulin autoantibodies (IAA) in the specimen. A microplate was coated with purified human insulin autoantibody (IAA) antibody to make a solid phase antibody. Insulin autoantibody (IAA) was added to the monoclonal antibody-coated microwells in turn, followed by HRP labeled insulin autoantibody (IAA ) The antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the insulin autoantibodies (IAA) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human insulin autoantibody (IAA) in the sample was calculated by a standard curve.
Sample processing and requirements:
1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage.
2. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation.
3. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen. After mixing for 10-20 minutes, centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again.
5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use.
6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
7. The sample containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP).
Precautions:
1. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
2. The sealing film is limited to one-time use to avoid cross-contamination.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag.
5. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5).
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
Kit composition:
Kit composition
48 hole configuration
96-well configuration
save
Instructions
1 serving
1 serving
Sealing film
2 pieces (48)
2 pieces (96)
sealed bag
1
1
Enzyme coated plate
1 × 48
1 × 96
Store at 2-8 ℃
Standard product: 2700ng / L
0.5ml × 1 bottle
0.5ml × 1 bottle
Store at 2-8 ℃
Standard dilution
1.5ml × 1 bottle
1.5ml × 1 bottle
Store at 2-8 ℃
Enzyme reagent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Sample diluent
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer A liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Developer B liquid
3 ml × 1 bottle
6 ml × 1 bottle
Store at 2-8 ℃
Stop solution
3ml × 1 bottle
6ml × 1 bottle
Store at 2-8 ℃
Concentrated washing liquid
(20ml × 20 times) × 1 bottle
(20ml × 30 times) × 1 bottle
Store at 2-8 ℃
Steps
1. Add sample: set up blank wells separately (the blank control wells do not add samples and enzyme-labeled reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
2. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of the standard products in the first and second wells, and then add the standard products in the first and second wells 50μl of diluent, mix well; then take 100μl from the first well and the second well and add them to the third and fourth wells respectively, and then add 50μl of standard diluent to the third and fourth wells respectively, mix well; Then take 50μl each in the third and fourth wells and discard it, then add 50μl each to the fifth and sixth wells, and then add 50ul of the standard dilution solution to the fifth and sixth wells respectively, and mix well; After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eight wells and add them to the ninth and tenth wells. Then add 50μl of the standard dilution solution to the ninth and tenth wells. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentration is 1800ng / L, 1200ng / L, 600ng / L, 300ng / L, 150ng / L)
3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 30 times (20 times of 48T) concentrated washing liquid with distilled water 30 times (20 times of 48T) and then use.
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat 5 times and pat dry.
6. Incubation: The operation is the same as 3.
7. Washing: The operation is the same as 5.
8. Color development: Add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop at 37 ° C in the dark for 15 minutes.
9. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
10. Termination: Add 50μl of stop solution to each well to stop the reaction (at this time the blue will turn to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Storage conditions and validity period:
1. Store the kit: 2-8 ℃.
2. Validity: 6 months
Kit performance:
1. The correlation coefficient R between the linear regression of the sample and the expected concentration is above 0.95.
2. The batch and approval shall be less than 9% and 11% respectively
examination range:
100ng / L -2000ng / L
Calculation:
Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply it by the dilution factor; Calculate the linear regression equation of the standard curve with the OD value, substitute the OD value of the sample into the equation, calculate the sample concentration, and multiply it by the dilution factor to obtain the actual concentration of the sample.
If you are in need of a stylish and functional storage solution for your home, a bookcase with a cabinet may be the perfect addition to your space. This versatile piece of furniture offers the best of both worlds, providing ample storage for books, decorative items, and other belongings, while also offering a closed cabinet space to keep clutter out of sight.
One of the primary benefits of a bookcase with a cabinet is its ability to maximize storage space in a compact footprint. The open shelving of the bookcase allows for easy access to your favorite books and decorative items, while the cabinet provides a hidden storage solution for items that you may not want on display. This makes it a great option for living rooms, home offices, or any other space where storage is a priority.
In addition to its functionality, a bookcase with a cabinet can also add a touch of style to your home. Many of these pieces feature sleek and modern designs, making them a stylish addition to any room. Whether you prefer a minimalist look or something more traditional, you can find a bookcase with a cabinet to suit your personal style and complement your existing decor.
Another advantage of a bookcase with a cabinet is its versatility. This piece of furniture can be used in a variety of ways to meet your specific needs. For example, you can use the open shelving to display your collection of books, while the cabinet can be used to store electronics, board games, or other items that you want to keep out of sight. You can also use the cabinet as a bar or a Media Console, making it a multifunctional addition to your home.
When shopping for a bookcase with a cabinet, there are a few factors to consider to ensure that you find the perfect piece for your space. First, consider the size and layout of the room where you plan to place the bookcase. You'll want to choose a piece that will fit comfortably in the space and complement the overall design of the room. Additionally, think about the specific storage needs that you have. If you have a large collection of books, you may want a bookcase with more shelves, while if you need to store larger items, you may prefer a bookcase with a larger cabinet space.
Finally, consider the materials and finishes available for bookcases with cabinets. You can choose from a variety of options, including wood, metal, and glass, each of which offers a unique look and feel. Consider the existing furniture and decor in the room to choose a bookcase with a cabinet that will complement your space.
In conclusion, a bookcase with a cabinet is a versatile and stylish storage solution that can enhance the functionality and aesthetic of any room. Whether you need a place to display your favorite books or a hidden storage solution for clutter, a bookcase with a cabinet offers the perfect combination of style and practicality. Consider adding one of these pieces to your home to maximize your storage space and add a touch of elegance to your living space.
Bookshelf Cabinet,Modern Bookshelves with Cabinet,Bookshelf Cabinet with Doors,White Bookcase with Cabinet
Ningbo Greenly Industy Co.,LTD. , https://www.chinagreenly.com